Patch-ID# 115193-07 Keywords: ct820 cp2300 sparc and smc firmware update Synopsis: Hardware/PROM: CP2300 SPARC and SMC firmware update Date: Jul/26/2004 Install Requirements: Additional instructions may be listed below Solaris Release: 8 SunOS Release: 5.8 Unbundled Product: Hardware/PROM Unbundled Release: SPARC 1.0.18 SMC 4.1.6 Xref: Topic: Relevant Architectures: sparc BugId's fixed with this patch: 5055792 5056659 5066210 Changes incorporated in this version: 5066210 5056659 5055792 Patches accumulated and obsoleted by this patch: Patches which conflict with this patch: Patches required with this patch: Obsoleted by: Files included with this patch: .FWupdate.info FWBin/CP2300.SMC.4.1.6.FLASH FWBin/CP2300.SPARC.1.0.18 FWBin/CP2300.SPARC.1.0.18_SMC.4.1.6 FWBin/CP2300.SPARC.1.0.18_SMC.4.1.6.README FWupdate Problem Description: 5066210 CP2300 loses system-banner and cgtp fails to configure when netconsole enabled 5056659 Power to SPARC is prematurely cut off if picl watchdog and CPU threshold are set 5055792 Communication breaks between KCS interface and local host & SMC. Patch Installation Instructions: -------------------------------- Refer to the special installation instructions described below. Special Install Instructions: ----------------------------- This patch has following files: FWupdate FWBin/CP2300.SPARC.1.0.18_SMC.4.1.6.README FWBin/CP2300.SPARC.1.0.18_SMC.4.1.6 FWBin/CP2300.SPARC.1.0.18 FWBin/CP2300.SMC.4.1.6.FLASH .FWupdate.info It has the supporting tool for updating the SPARC and/or SMC firmwares. Tool Name : FWupdate Purpose : To initiate system firmware update (SPARCFW & SMCFW) at Solaris level. User : Must be Super User to execute this script Usage : FWupdate [-h] FWupdate [-F] -f -d -t -h : Help, show usage -F : To Force the update when the Firmware is being downgraded -f : Complete filepath & filename specified by following argument -t : Type of Firmware binary. Possible options={sparc, smc, sparc+smc} -d : Complete path of device node or device alias specifying the device where file is located If disk is specified, the file must be in the root directory. Also, the file cannot of a Symbolic link Points of interest: 1) The complete filepath & filename must be specified using -f option. 2) Use -d option to specify the device from which the file may be loaded. User may specify the device either using a OBP device alias or using the complete path to the device node. 3) If the file is located on a local disk then it must be in the root directory and must not be a symbolic link. 4) The tool performs a check on the version of SPARC Firmware. If a downgrade is detected then the script would notify the user. A downgrade can only be updated using the force (-F) option. 5) Tool does not performs a check on SMCFW version. 6) Update script FWupdate and info file FWupdate.info must be in same directory. Sample usage: Example 1: ./FWupdate -f /CP2300.SPARC.1.0.18_SMC.4.1.6 -d net -t sparc+smc File is accessible from the TFTP boot server and is combined OBP & SMC image For example 2 and 3, make sure the binary file is in the root directory of the disk. The example is for a PMC disk in slot A. If the PMC disk is in slot B, then use "pmc1/disk" instead of "pmc0/disk". Example 2: ./FWupdate -f /CP2300.SPARC.1.0.18_SMC.4.1.6 -d pmc0/disk -t sparc+smc File is on a local disk in root directory Example 3: ./FWupdate -f /CP2300.SMC.4.1.6.FLASH -d pmc0/disk -t smc File is SMC flash binary located on local disk README -- Last modified date: Monday, July 26, 2004