Patch-ID# 112140-03 Keywords: netra LOM Synopsis: Netra Lights Out Management 2.0: Lomlite2 lom_update_eeprom patch Date: Jan/07/2003 Install Requirements: Additional instructions may be listed below Solaris Release: 8 SunOS Release: 5.8 Unbundled Product: Netra Lights Out Management Unbundled Release: 2.0 Xref: Topic: Lomlite2 configuration data update patch Relevant Architectures: sparc NOTE: netra t1 200, netra 20 BugId's fixed with this patch: 4417373 4480653 4658786 4665760 Changes incorporated in this version: 4665760 Patches accumulated and obsoleted by this patch: Patches which conflict with this patch: Patches required with this patch: 110208-07 or greater Obsoleted by: Files included with this patch: lom_update_eeprom Problem Description: 4665760 Netra T1 AC/DC 200 / SF V120 have -12v supply warnings at high temperatures 4658786 LOM config change mechanism requires update for Netra 20 4480653 Mechanism to deliver LOM firmware config files required. 4417373 VDD_core check voltage appears to be wrong in FJ2-V1.1-258-7884-06.es Patch Installation Instructions: -------------------------------- This patch is only applicable to the following architecture(s). Netra T1 200 Netra 20 and will not update the configuration on other architectures. The changes for Netra 20 are for machines that have been upgraded from 750MHz to 900MHz only. The Lomlite2 eeprom configuration data will only get updated when the 900MHz cpu module(s) have been installed. This is not an OS patch and is not installed with the standard patchadd(1M) command. After unpacking the patch, follow the "Special Install Instructions" below to upgrade the Lomlite2 eeprom configuration data. This patch is not OS-dependent. The list of releases shown under the "Solaris Release" and "SunOS Release" sections may not be complete. The absence of the running Solaris Release or SunOS Release from the lists above does not preclude the installation of this patch on the hardware. Special Install Instructions: ----------------------------- ************************************************************************** ************************************************************************** **WARNING:****WARNING:****WARNING:****WARNING:****WARNING:****WARNING:** * PLEASE READ THE INSTRUCTIONS CAREFULLY AND ENTIRELY. PLEASE FOLLOW THE INSTRUCTIONS EXACTLY AS THEY ARE STATED. * FAILURE TO FOLLOW INSTRUCTIONS COULD EITHER RESULT IN A DEFECTIVE BOARD OR UNSUCCESSFUL UPDATE. * THIS IS NOT A STANDARD PATCH in that it does not use the installpatch and backoutpatch scripts. * TAKE EVERY PRECAUTION TO ENSURE THAT THE UPGRADE IS NOT INTERRUPTED ONCE IT IS STARTED! **WARNING:****WARNING:****WARNING:****WARNING:****WARNING:****WARNING:** ************************************************************************** ************************************************************************** The patch delivers new configuration data that can be applied through the use of the following command. # ./lom_update_eeprom This will return with a confirmation request to which the user must respond with 'C' if they wish to continue. The update process may take a short time after which the LOM will reset itself. README -- Last modified date: Tuesday, January 7, 2003